Sunday, February 24, 2008

7.24 You have small eyes

(A General Electric 1.5 Tesla Signa MR scanner with a head coil inside the bore)

Enough fun with the Singapore sling, now we move on to something intriguing.

Despite the outward appearance, all emmetropic and hyperopic eyeballs are pretty much the same in size. The myopic eyes are indeed a little bigger. And once in a while, we need to inform a patient, "You have small eyes." This is not being impolite, but to point out the presence of nanophthalmos (dwarf eye). Nanopthalmos is not to be confused with microphthalmia (small eye); the latter is a congenital malformation with other developmental issues, often from fetal alcohol syndrome or viral infection in utero. Patients with hereditary nanophthalmos may have a defective gene on Chromosome 11; otherwise, they are developmentally normal.

Nanophthalmos with uveal effusion is a nasty condition first described by Dr Robert Brockhurst of Boston, Massachusetts, in 1974. These patients often develop narrow-angle glaucoma that prompted surgical intervention. Unfortunately, this also results in secondary retinal and choroidal detachment - owing to uveal effusion. Further repair is ineffective and sometimes choroidal elevation can be mistaken as intraocular tumors. So the recognition of nanophthalmos is important in order to manage it correctly.

Maybe this is a good time to look at the size of human eyeballs. We have been able to convince some patients to volunteer for MR imaging of the eye:

Table I. Refractive error of patients and volunteers (5 eyes/group).

Type of Eye

Mean ± SD (diopter)

Range (diopter)

Nanophthalmos (phakic)

+10.42 ± 6.22

+4.50 – +18.50

Hyperopia

+3.42 ± 0.66

+3.00 - +4.50

Emmetropia

+0.21 ± 0.25

-0.25 - +0.50

Myopia

-10.25 ± 4.31

-6.25 - -15.50


Notice the nanophthalmic eyes all have very high hyperopia which in fact is one of the diagnostic indices.

And from MR images, it is possible to calculate the size of the eyeballs in 3D:

Table II. Ocular dimensions (mean ± SD mm) determined from MR images.

Type of Eye

Axial1

Equatorial1

Coronal(H)

Coronal(V)

Nanophthalmos

18.1 ± 2.02

19.0 ± 2.62

19.3 ± 3.02

18.2 ± 2.52

Hyperopia3

23.1 ± 1.0

24.1 ± 0.5

23.8 ± 0.3

23.3 ± 1.4

Emmetropia

22.9 ± 1.3

23.9 ± 1.2

23.9 ± 1.5

23.0 ± 1.9

Myopia4

28.5 ± 1.0

27.1 ± 1.5

28.3 ± 0.5

27.4 ± 0.7

1The equatorial lengths are significantly greater than the axial lengths: paired t-test P=0.006 and 0.025 for emmetropia and hyperopia, respectively. For nanophthalmic eyes, P=0.1 and for myopia, P=0.2.
2
Unpaired t-tests between nanophthalmos and emmetropia in all dimensions, P<0.02.

3No difference between hyperopia and emmetropia.
4Unpaired t-tests between myopia and emmetropia in all dimensions P<0.01.

Clearly, myopic eyes are big. And in contrast, nanophthalmic eyes are much smaller which is the hallmark of nanophthalmos.

If we look at the anterior segment closely:

Table III. Anterior segment dimensions (mean ± SD mm).

Type of Eye

Ant. Chamber Depth

Lens Thickness

Lens Diameter

Nanophthalmos

3.0 ± 0.11

5.3 ± 0.82

8.5 ± 0.4

Hyperopia3

3.1 ± 0.3

4.6 ± 0.6

8.7 ± 0.4

Emmetropia

3.0 ± 0.2

5.0 ± 0.8

8.4 ± 0.4

Myopia4

2.6 ± 0.6

4.0 ± 0.3

9.4 ± 1.3

1Unpaired t-test when calculated as % axial length between nanophthalmos (16.5±2.5) and emmetropia (13.0±1.1): P=0.025.
2
Unpaired t-test when calculated as % axial length between nanophthalmos (29.5±7.2) and emmetropia (21.7±2.9): P=0.06.
3
No significant difference between hyperopia and emmetropia.
4
No significant difference between emmetropia and myopia.

Hmm, the anterior chamber depth and the lens size in nanophthalmos are both similar to normal emmetropic and hyperopic eyes. So what else has gone wrong?

Table IV. Choroidal and scleral thickness (mean ± SD mm).


Axial

Vertical

Equatorial

Type of Eye

Choroid

Sclera

Choroid1

Sclera

Choroid

Sclera2

Naophthalmos

0.7±0.3

0.7±0.3

0.7±0.3

0.5±0.2

0.6±0.3

0.7±0.3

Hyperopia3

1.0±0.0

0.7±0.3

0.4±0.2

0.4±0.2

0.5±0.3

0.4±0.3

Emmetropia

0.9±0.2

0.6±0.3

0.5±0.1

0.4±0.2

0.5±0.2

0.4±0.2

Myopia4

N.M.

N.M.

N.M.

N.M.

N.M.

N.M.

1Unpaired t-test between nanophthalmos and emmetropia: P<0.09; when calculated as % of total vertical axial length, nanophthalmos (4.0±1.8) vs. emmetropia (1.9±0.5): P<0.04. 2Unpaired t-test between nanophthalmos and emmetropia: P<0.08; when calculated as % of total equatorial axial length, nanophthalmos (3.4±1.4) vs. emmetropia (1.6±0.5): P=0.03. 3No difference between hyperopia and emmetropia. 4N.M. - Not measurable. Thicknesses less than the in-plane resolution of 0.31mm.

Ah, so that's it: the equatorial sclera is the thickest in the nanopthalmic eyes. It is almost like all eyes are given the same amount of building materials. Smaller eyes are constructed with thicker walls while larger (myopic) eyes with thinner walls. Thick equatorial sclera chokes off blood circulation through the vortex veins (each eye has 4 or 6 of these). The only effective treatment for relieving high eye pressure is therefore sclerostomy around the base of the vortex veins.

For those who have patiently read through the above, a bonus for you. We'll now show you how to perform high-resolution MRI of the eye (also the methodology used in the study described above):

MR imaging was conducted using General Electric 1.5 Tesla Signa body scanners. A home-made 1.25-inch receive-only surface coil tuned to the proton frequency of the imagers was placed over the eye of interest. [Note: the factory 3-inch TMJ coil also can be used.] The coil was constructed with variable capacitors that allowed tuning and matching. A sagittal head image series using an FOV of 20 mm or more was acquired to locate the eye. Slice selection in the axial plane was then determined using graphic prescription. Multi-slice images in the axial and coronal planes were obtained (usually 8-9 slices/plane/eye) using a T1-weighted spin-echo sequence with for example, TR/TE = 400/20 msec with an image resolution of 0.31 x 0.31 mm and a slice thickness of 3 mm (in this case, the image acquisition time was 4.5 min). Image slices was selected by aligning imaging planes as parallel to the antero-posterior axis as possible.

No comments:

Post a Comment